- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources1
- Resource Type
-
0000000001000000
- More
- Availability
-
10
- Author / Contributor
- Filter by Author / Creator
-
-
Darr, Matthew (1)
-
Heitman, Josh (1)
-
Horton, Robert (1)
-
Ramirez_Reyes, Alam (1)
-
Taylor, Katherine (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
& Abramson, C. I. (0)
-
& Abreu-Ramos, E. D. (0)
-
& Adams, S.G. (0)
-
& Ahmed, K. (0)
-
& Ahmed, Khadija. (0)
-
& Aina, D.K. Jr. (0)
-
& Akcil-Okan, O. (0)
-
& Akuom, D. (0)
-
& Aleven, V. (0)
-
& Andrews-Larson, C. (0)
-
& Archibald, J. (0)
-
& Arnett, N. (0)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Abstract Plastic liners are sometimes used with soil samplers in order to collect and store intact soil cores. Gaps at the soil–wall interface caused by the flexibility of plastic liners can result in wall flow, preventing accurate fluid flux density measurements. A subsampling method was developed to overcome problems with wall flow from soil samples collected with plastic liners in order to measure air permeability (ka) and saturated hydraulic conductivity (Ksat) on the intact cores. Subsamples were obtained after first immobilizing the soil within plastic liners by injecting expanding foam into the gaps between the soil and the liners. Once the soil was fixed in place, the soil samples were cut to the desired length, and sharpened metal rings were inserted into the original soil sample with a vise. With the metal ring at the desired depth, the subsample was removed from the original soil sample by cutting the liner and removing excess soil from the ends of the rings. Initial attempts to measurekaandKsaton samples within the original liners led to unrealistically high values because significant wall flow occurred. However, after implementing the improved subsampling approach, the measuredkaandKsatof the subsamples were within the range of expected values based on the literature. The subsampling method effectively eliminated wall flow on soil originally collected in plastic liners and is relatively easy to implement without the need for specialized tools.more » « less
An official website of the United States government
